Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2020, 07:24 AM
  • 18 0515_18 0514_07072020_003728.mp4

Date
07/07/2020
W/O
838907
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00705
PipeID
P14369
Time
12:24 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7818
Sewer Name
SOUTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_838907_TV18194_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0515
Downstream MH
18 0514
Dir. of Survey
Downstream
Length Surveyed
343.9 ft.
Total Length
343.9 ft.
Structural Index
3
Structural Quick
3G23
Structural Rating
120
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
120
Pipe schematic from manhole 18 0515 to 18 0514
MH: 18 0515MH: 18 0514downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 05150 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 15 %of cross sectional area2.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES29.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 4"36.1 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES55.5 ft. TB - Tap Break-In, at 09 o'clock, -, within 8 inches of joint: NO, 4"60.9 ft. CS - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES101.5 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES138 ft. FS - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES141.8 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES173.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start296.6 ft. FS - Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES341.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish343.9 ft. AMH - Downstream Manhole, Survey Ends - 18 0514

Observation photos (8)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    36.1 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

    60.9 ft. - Crack Spiral, from 12 to 03 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    101.5 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

    138 ft. - Fracture Spiral, from 02 to 05 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    141.8 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    173.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

    296.6 ft. - Fracture Spiral, from 03 to 04 o'clock, within 8 inches of joint: YES

Observations (15)

DistanceCodeObservation
55.5TB
173.9CM
341.7CM
36.1CL
60.9CS
0AMH18 0515
343.9AMH18 0514
0MWM
2.7CM
101.5CL
296.6FS
29.3TB
138FS
141.8FL
0MWL

Properties (7)

additional_info
SC411628
custom_field_three
CRACKS, FRACTURES
custom_field_two
2
customer
1
datetime
2020-07-07T00:24:04-07:00
documentation
PROPIPE
is_lateral_inspection
false