Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 7, 2020, 06:01 AM
  • 18 0511_18 0510_07072020_000531.mp4

Date
07/06/2020
W/O
838907
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00705
PipeID
P14365
Time
11:01 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7818
Sewer Name
SOUTH PLANT OUTFALL TRUNK
City
WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_838907_TV18194_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
21 in.
Width
21 in.
Upstream MH
18 0511
Downstream MH
18 0510
Dir. of Survey
Downstream
Length Surveyed
595.8 ft.
Total Length
595.8 ft.
Structural Index
3
Structural Quick
3522
Structural Rating
19
O&M Index
2
O&M Quick
412T
O&M Rating
214
Overall Index
2
Overall Quick
Overall Rating
233
Pipe schematic from manhole 18 0511 to 18 0510
MH: 18 0511MH: 18 0510downstream0 ft. MWL - Water Level, 40 %of cross sectional area0 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 051144 ft. FC - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES57.4 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES70.2 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start - SLUDGE219.5 ft. TF - Tap Factory Made, at 01 o'clock, -, within 8 inches of joint: NO, 6"335.4 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES495.2 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES534.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6"543.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES591.2 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start595.8 ft. MSA - Survey Abandoned - SLUDGE595.8 ft. DSC - Deposits Settled Compacted, 10 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish595.8 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Finish

Observation photos (6)

  • Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

    44 ft. - Fracture Circumferential, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    57.4 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    335.4 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    495.2 ft. - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    543.8 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start

    591.2 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: NO, Start

Observations (15)

DistanceCodeObservation
0MWL
0MWM
57.4FL
335.4CL
543.8FL
591.2FL
0AMH18 0511
595.8MSASLUDGE
44FC
495.2FL
70.2DSCSLUDGE
219.5TF
534.6TF
595.8DSC
595.8FL

Properties (7)

additional_info
SC411628
custom_field_three
CRACKS, FRACTURES
custom_field_two
2
customer
1
datetime
2020-07-06T23:01:17-07:00
documentation
PROPIPE
is_lateral_inspection
false