Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2020, 07:01 AM
  • 02 1389_02 1388 _06232020_000736.mp4

Date
06/23/2020
W/O
833859
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00242
PipeID
P03907
Time
12:01 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7739
Sewer Name
CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_833859_TV02041_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
27 in.
Upstream MH
02 1388
Downstream MH
02 1389
Dir. of Survey
Upstream
Length Surveyed
7.2 ft.
Total Length
7.2 ft.
Structural Index
3
Structural Quick
4131
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 02 1388 to 02 1389
MH: 02 1388MH: 02 1389upstream0 ft. MSA - Survey Abandoned - CAM BLKD BY OFFSET JOINT0 ft. MWLS - Water Level, Sag in pipe, 90 %of cross sectional area0.4 ft. JOM - Joint Offset Medium3.1 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES7.2 ft. AMH - Downstream Manhole, Survey Begins - 02 13887.2 ft. MWM - Water Mark, 15 %of cross sectional area7.2 ft. MWL - Water Level, 5 %of cross sectional area

Observation photos (4)

  • Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    4.1 ft. - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Joint Offset Medium

    6.8 ft. - Joint Offset Medium

  • Survey Abandoned - CAM BLKD BY OFFSET JOINT

    7.2 ft. - Survey Abandoned - CAM BLKD BY OFFSET JOINT

  • Water Level, Sag in pipe, 90 %of cross sectional area

    7.2 ft. - Water Level, Sag in pipe, 90 %of cross sectional area

Observations (7)

DistanceCodeObservation
4.1FL
0AMH02 1388
7.2MSACAM BLKD BY OFFSET JOINT
7.2MWLS
0MWM
0MWL
6.8JOM

Properties (6)

additional_info
SC411398
custom_field_two
5
customer
1
datetime
2020-06-23T00:01:30-07:00
documentation
PROPIPE
is_lateral_inspection
false