Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2020, 07:08 AM
  • 02 1388_02 1387 _06232020_002545.mp4

Date
06/23/2020
W/O
833859
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00242
PipeID
P03906
Time
12:08 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7739
Sewer Name
CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_833859_TV02041_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1388
Downstream MH
02 1387
Dir. of Survey
Downstream
Length Surveyed
351.5 ft.
Total Length
351.5 ft.
Structural Index
2
Structural Quick
3123
Structural Rating
9
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
2
Overall Quick
Overall Rating
12
Pipe schematic from manhole 02 1388 to 02 1387
MH: 02 1388MH: 02 1387downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13880 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area3.6 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES32.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES43.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"75.7 ft. CL - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES85.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start94.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"136.9 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - DEFECTIVE SEAL144.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"194.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"244.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"294.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"344.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"351.5 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish351.5 ft. AMH - Downstream Manhole, Survey Ends - 02 1387

Observation photos (5)

  • Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

    3.6 ft. - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    32.7 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

    75.7 ft. - Crack Longitudinal, at 09 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    85.7 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - DEFECTIVE SEAL

    136.9 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - DEFECTIVE SEAL

Observations (17)

DistanceCodeObservation
194.1TFC
85.7CM
144.1TFC
136.9TBIDEFECTIVE SEAL
294.8TFC
351.5CM
94.2TFC
32.7CL
344.5TFC
244.3TFC
0AMH02 1388
43.6TFC
0MWL
351.5AMH02 1387
3.6FC
0MWM
75.7CL

Properties (7)

additional_info
SC411398
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-23T00:08:46-07:00
documentation
PROPIPE
is_lateral_inspection
false