Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 23, 2020, 07:26 AM
  • 02 1387_02 1386 _06232020_004219.mp4

Date
06/23/2020
W/O
833859
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00242
PipeID
P03905
Time
12:26 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7739
Sewer Name
CLOVERLAWN TRUNK
City
PARAMOUNT
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
31
Purpose
Routine Assessment
Project
WO_833859_TV02041_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
24 in.
Upstream MH
02 1387
Downstream MH
02 1386
Dir. of Survey
Downstream
Length Surveyed
340.7 ft.
Total Length
340.7 ft.
Structural Index
3
Structural Quick
413M
Structural Rating
220
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
220
Pipe schematic from manhole 02 1387 to 02 1386
MH: 02 1387MH: 02 1386downstream0 ft. AMH - Upstream Manhole, Survey Begins - 02 13870 ft. MWL - Water Level, 5 %of cross sectional area0 ft. MWM - Water Mark, 15 %of cross sectional area5.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start20 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES30.8 ft. FC - Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES32 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES32.5 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"42.4 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"91.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"142 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"195.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6" - CRACKED CAP201 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES224 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES234.9 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES333 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES340.7 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish340.7 ft. AMH - Downstream Manhole, Survey Ends - 02 1386

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    5.3 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES

    30.8 ft. - Fracture Circumferential, from 01 to 05 o'clock, within 8 inches of joint: YES

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    32.5 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    234.9 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    333 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (18)

DistanceCodeObservation
30.8FC
0AMH02 1387
333FS
224FM
20FC
201FL
142TFC
0MWL
32.5TB
0MWM
340.7CM
42.4TFC
91.6TFC
32FC
340.7AMH02 1386
5.3CM
195.9TFCCRACKED CAP
234.9FS

Properties (7)

additional_info
SC411398
custom_field_three
MULTIPLE CRACKS/ SOME FRACTURE'S
custom_field_two
3
customer
1
datetime
2020-06-23T00:26:11-07:00
documentation
PROPIPE
is_lateral_inspection
false