- Date
- 07/15/2020
- W/O
- 838889
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00033
- PipeID
- P10115
- Time
- 11:59 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7921
- Sewer Name
- JOINT OUTFALL F - UNIT 1
- City
- long beach
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 03
- Page No.
- 01
- Purpose
- Routine Assessment
- Project
- RFIR_WO_838889_TV03167_JUL2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 69 in.
- Width
- 12 in.
- Upstream MH
- F 0025
- Downstream MH
- F 0024
- Dir. of Survey
- Downstream
- Length Surveyed
- 480 ft.
- Total Length
- 480 ft.
- Structural Index
- 4
- Structural Quick
- 5e3R
- Structural Rating
- 1433
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 1433
Pipe schematic from manhole F 0025 to F 0024 Observation photos (2)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

2.2 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start