Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2020, 08:40 AM
  • 02 1235_02 1234_07292020_014625.mp4

Date
07/29/2020
W/O
838890
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00303
PipeID
P18787
Time
1:40 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7933
Sewer Name
SANTA ANITA OUTFALL TRUNK
City
montebello
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
14
Purpose
Routine Assessment
Project
WO_838890_TV02300_JUL2020
Sewer Type
Siphon
Material
CIP
Shape
Circular
Height
18 in.
Width
18 in.
Upstream MH
02 1235
Downstream MH
02 1234
Dir. of Survey
Downstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
3
O&M Quick
3100
O&M Rating
3
Overall Index
3
Overall Quick
Overall Rating
6
Pipe schematic from manhole 02 1235 to 02 1234
MH: 02 1235MH: 02 1234downstream0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 1235 WEST2 ft. DAZ - Deposits Attached Other, 20 %of cross sectional area, from 05 to 07 o'clock, , within 8 inches of joint: YES2.1 ft. SCP - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MSA - Survey Abandoned - DOWN LEG SIPHON FROM UP STREAM MH

Observation photos (2)

  • Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES

    2.1 ft. - Surface Corrosion Metal Pipe, from 08 to 04 o'clock, within 8 inches of joint: YES

  • Survey Abandoned - DOWN LEG SIPHON FROM UP  STREAM MH

    2.1 ft. - Survey Abandoned - DOWN LEG SIPHON FROM UP STREAM MH

Observations (6)

DistanceCodeObservation
0MWM
2.1SCP
2DAZ
0MWL
0AMH02 1235 WEST
2.1MSADOWN LEG SIPHON FROM UP STREAM MH

Properties (7)

additional_info
SC411793
custom_field_three
SURFACE CORROSION
custom_field_two
3
customer
1
datetime
2020-07-29T01:40:17-07:00
documentation
PROPIPE
is_lateral_inspection
false