Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 29, 2020, 10:03 AM
  • 01 BULLIS_01 1314_07292020_031505.mp4

Date
07/29/2020
W/O
838875
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00198
PipeID
P02193
Time
3:03 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7934
Sewer Name
BULLIS ROAD-TEMPLE STREET RELIEF TRUNK
City
COMPTON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 01
Page No.
16
Purpose
Routine Assessment
Project
RFIR_WO_838875_TV01273_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
33 in.
Width
15 in.
Upstream MH
01 1314
Downstream MH
01 BULLIS
Dir. of Survey
Upstream
Length Surveyed
131.9 ft.
Total Length
132 ft.
Structural Index
3
Structural Quick
413D
Structural Rating
131
O&M Index
2
O&M Quick
2D00
O&M Rating
50
Overall Index
2
Overall Quick
Overall Rating
181
Pipe schematic from manhole 01 1314 to 01 BULLIS
MH: 01 1314MH: 01 BULLISupstream0 ft. AMH - Upstream Manhole, Survey Ends - 01 BULLIS0.1 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: YES, 4"3 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish89.7 ft. FM - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES114.7 ft. CL - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES130 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start130 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start130 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start132 ft. MWL - Water Level, 25 %of cross sectional area132 ft. MWM - Water Mark, 30 %of cross sectional area132 ft. AMH - Downstream Manhole, Survey Begins - 01 1314

Observation photos (2)

  • Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

    17.3 ft. - Crack Longitudinal, at 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

    42.3 ft. - Fracture Multiple, from 09 to 10 o'clock, within 8 inches of joint: YES

Observations (13)

DistanceCodeObservation
2CM
0MWL
0MWM
42.3FM
2SSS
2DAGS
132AMH01 BULLIS
129SSS
0AMH01 1314
131.9TBA
129DAGS
17.3CL
129CM

Properties (8)

additional_info
SC411793
custom_field_three
MULTIPLE FRACTURE
custom_field_two
3
customer
1
datetime
2020-07-29T03:03:46-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
31028