- Date
- 06/17/2020
- W/O
- 833710
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00713
- PipeID
- P13849
- Time
- 11:37 PM
- Certificate
- U-715-07000770
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7802
- Sewer Name
- 18 WALNUT WAY TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833710_TV18059_JUN2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0033
- Downstream MH
- 18 0032
- Dir. of Survey
- Downstream
- Length Surveyed
- 320.8 ft.
- Total Length
- 320.8 ft.
- Structural Index
- 3
- Structural Quick
- 4I3L
- Structural Rating
- 517
- O&M Index
- 2
- O&M Quick
- 2L14
- O&M Rating
- 138
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 655
Pipe schematic from manhole 18 0033 to 18 0032 Observation photos (5)

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

15.8 ft. - Roots Fine Connection, from 08 to 10 o'clock

54 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

78 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

81.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start