- Date
- 07/01/2020
- W/O
- 833710
- Weather
- Dry
- Operator/Surveyor
- EN. RUIZ
- Sewer ID
- Z00713
- PipeID
- P13835
- Time
- 11:44 PM
- Certificate
- U-116-07001919
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7773
- Sewer Name
- 18 WALNUT WAY TRUNK
- City
- WHITTIER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833710_TV18059_JUN2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 18 0019
- Downstream MH
- 18 0018
- Dir. of Survey
- Downstream
- Length Surveyed
- 372 ft.
- Total Length
- 372 ft.
- Structural Index
- 3
- Structural Quick
- 413N
- Structural Rating
- 374
- O&M Index
- 2
- O&M Quick
- 2100
- O&M Rating
- 2
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 376
Pipe schematic from manhole 18 0019 to 18 0018 Observation photos (7)

0 ft. - General Observation - ROACHES @ MH

2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

2.6 ft. - General Observation - 40% MAG COAT

118.7 ft. - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES

124.5 ft. - Fracture Multiple, from 12 to 01 o'clock, within 8 inches of joint: YES

169.6 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 09 o'clock, , within 8 inches of joint: YES

372 ft. - General Observation - ROACHES @ MH