Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 8, 2020, 06:15 AM
  • 18 0933_18 0932_07072020_233255.mp4

Date
07/07/2020
W/O
838885
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00700
PipeID
P14781
Time
11:15 PM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7821
Sewer Name
SCOTT AVENUE TRUNK
City
WHITTIER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
21
Purpose
Routine Assessment
Project
RFIR_WO_838885_TV18118_JUL2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Width
8 in.
Upstream MH
18 0933
Downstream MH
18 0932
Dir. of Survey
Downstream
Length Surveyed
86.9 ft.
Total Length
86.9 ft.
Structural Index
4
Structural Quick
514B
Structural Rating
69
O&M Index
2
O&M Quick
412B
O&M Rating
36
Overall Index
3
Overall Quick
Overall Rating
105
Pipe schematic from manhole 18 0933 to 18 0932
MH: 18 0933MH: 18 0932downstream0 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK0 ft. MWL - Water Level, 25 %of cross sectional area0 ft. MWM - Water Mark, 50 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 18 09333.5 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start5.2 ft. FM - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES7.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.2 ft. BVV - Broken Void Visible, from 01 to 05 o'clock, within 8 inches of joint: YES13.6 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"22.4 ft. TF - Tap Factory Made, at 03 o'clock, -, within 8 inches of joint: NO, 6"71.1 ft. TFC - Tap Factory Made Capped, at 09 o'clock, -, within 8 inches of joint: NO, 6"73.9 ft. TFC - Tap Factory Made Capped, at 03 o'clock, -, within 8 inches of joint: NO, 6"83.6 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish83.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish86.9 ft. AMH - Downstream Manhole, Survey Ends - 18 093286.9 ft. MGO - General Observation - CONNECTION AT MH, 9 O'CLOCK

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    3.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

    5.2 ft. - Fracture Multiple, from 08 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.2 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Broken Void Visible, from 01 to 05 o'clock, within 8 inches of joint: YES

    7.2 ft. - Broken Void Visible, from 01 to 05 o'clock, within 8 inches of joint: YES

Observations (16)

DistanceCodeObservation
86.9AMH18 0932
0MGOCONNECTION AT MH, 9 O'CLOCK
86.9MGOCONNECTION AT MH, 9 O'CLOCK
83.6DAGS
7.2FM
0MWL
5.2FM
0MWM
73.9TFC
7.2BVV
22.4TF
3.5DAGS
83.6FM
0AMH18 0933
13.6TFC
71.1TFC

Properties (7)

additional_info
SC411631
custom_field_three
BROKEN, SEVERE FRACTURES
custom_field_two
1
customer
1
datetime
2020-07-07T23:15:24-07:00
documentation
PROPIPE
is_lateral_inspection
false