- Date
- 07/07/2020
- W/O
- 83885
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00700
- PipeID
- P14777
- Time
- 11:49 PM
- Certificate
- U-715-070007708
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7821
- Sewer Name
- SCOTT AVENUE TRUNK
- City
- WHITTIER
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 18
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_838885_TV18118_JUL2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 10 in.
- Width
- 10 in.
- Upstream MH
- 18 0929
- Downstream MH
- 18 0928
- Dir. of Survey
- Downstream
- Length Surveyed
- 352.8 ft.
- Total Length
- 352.8 ft.
- Structural Index
- 4
- Structural Quick
- 4M00
- Structural Rating
- 272
- O&M Index
- 2
- O&M Quick
- 2M00
- O&M Rating
- 142
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 414
Pipe schematic from manhole 18 0929 to 18 0928 Observation photos (3)

3 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

9.1 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

73.3 ft. - Tap Factory Made Defective, at 09 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN AT CONNECTION