Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 15, 2020, 10:25 AM
  • 05 0398_05 0397_06152020_034920.mp4

Date
06/15/2020
W/O
833501
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05610
Time
3:25 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7730
Sewer Name
DISTRICT #5 MAIN RELIEF TRUNK
City
LENNOX
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_833501_TV05179_JUN2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
27 in.
Width
30 in.
Upstream MH
05 0398
Downstream MH
05 0397
Dir. of Survey
Downstream
Length Surveyed
441.2 ft.
Total Length
441.2 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
3
Overall Quick
Overall Rating
9
Pipe schematic from manhole 05 0398 to 05 0397
MH: 05 0398MH: 05 0397downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 03980 ft. MWM - Water Mark, 55 %of cross sectional area0 ft. MWL - Water Level, 35 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.1 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start441.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish441.2 ft. AMH - Downstream Manhole, Survey Ends - 05 0397441.2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (1)

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (8)

DistanceCodeObservation
0AMH05 0398
0MWM
441.2AMH05 0397
2.1SAV
2.1SSS
441.1SAV
441.2SSS
0MWL

Properties (7)

additional_info
SC411388
custom_field_three
AGGREGATE VISIBLE/SPALLING
custom_field_two
3
customer
1
datetime
2020-06-15T03:25:17-07:00
documentation
PROPIPE
is_lateral_inspection
false