Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 26, 2020, 06:33 AM
  • 05 0387_05 0386_06252020_235348.mp4

Date
06/25/2020
W/O
833501
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00432
PipeID
P05599
Time
11:33 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7747
Sewer Name
DISTRICT #5 MAIN RELIEF TRUNK
City
HAWTHORNE
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
10
Purpose
Routine Assessment
Project
RFIR_WO_833501_TV05179_JUN2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
05 0387
Downstream MH
05 0386
Dir. of Survey
Downstream
Length Surveyed
342.6 ft.
Total Length
342.6 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
4
O&M Quick
4100
O&M Rating
4
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole 05 0387 to 05 0386
MH: 05 0387MH: 05 0386downstream0 ft. MWL - Water Level, 35 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 03870 ft. MWM - Water Mark, 70 %of cross sectional area2.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start167 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"342.6 ft. AMH - Downstream Manhole, Survey Ends - 05 0386342.6 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (2)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    167 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (7)

DistanceCodeObservation
0MWL
342.6AMH05 0386
2.1SAV
342.6SAV
0AMH05 0387
0MWM
167TB

Properties (5)

additional_info
SC411756
customer
1
datetime
2020-06-25T23:33:54-07:00
documentation
PROPIPE
is_lateral_inspection
false