- Date
- 06/26/2020
- W/O
- 833501
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00432
- PipeID
- P05584
- Time
- 2:35 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7747
- Sewer Name
- DISTRICT #5 MAIN RELIEF TRUNK
- City
- HAWTHORNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 13
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833501_TV05179_JUN2020
- Sewer Type
- Gravity
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 30 in.
- Width
- 33 in.
- Upstream MH
- 05 0368
- Downstream MH
- 05 0367
- Dir. of Survey
- Downstream
- Length Surveyed
- 330.8 ft.
- Total Length
- 330.8 ft.
- Structural Index
- 4
- Structural Quick
- 5432
- Structural Rating
- 26
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 4
- Overall Quick
- —
- Overall Rating
- 31
Pipe schematic from manhole 05 0368 to 05 0367 Observation photos (6)

2.5 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

63.8 ft. - Surface Reinforcement Visible, from 01 to 02 o'clock, within 8 inches of joint: NO

70.6 ft. - Surface Reinforcement Visible, from 10 to 12 o'clock, within 8 inches of joint: NO

72.9 ft. - Surface Reinforcement Visible, from 10 to 02 o'clock, within 8 inches of joint: NO, Start

73.4 ft. - Surface Aggregate Projecting, from 10 to 02 o'clock, within 8 inches of joint: YES

284.6 ft. - Surface Reinforcement Visible, at 12 o'clock, within 8 inches of joint: NO