- Date
- 06/02/2020
- W/O
- 834129
- Weather
- Dry
- Operator/Surveyor
- S. LOPEZ
- Sewer ID
- Z00093
- PipeID
- P08963
- Time
- 1:38 AM
- Certificate
- U-111-11880
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7681
- Sewer Name
- JOINT OUTFALL B - UNIT 5C
- City
- PASADENA
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 16
- Page No.
- 11
- Purpose
- Routine Assessment
- Project
- RFIR_WO_834129_TV16034_JUN2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 21 in.
- Width
- 57 in.
- Upstream MH
- B 0451
- Downstream MH
- B 0450
- Dir. of Survey
- Downstream
- Length Surveyed
- 175.4 ft.
- Total Length
- 175.4 ft.
- Structural Index
- 3
- Structural Quick
- 3F2F
- Structural Rating
- 170
- O&M Index
- 2
- O&M Quick
- 312F
- O&M Rating
- 71
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 241
Pipe schematic from manhole B 0451 to B 0450 Observation photos (5)

2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

2 ft. - General Observation - 80% MAG COAT

2 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

2 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

80.1 ft. - Roots Medium Connection, from 08 to 12 o'clock, 25 %, within 8 inches of joint: YES - 25% ROOTS