Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 12, 2020, 07:24 AM
  • 19 0214_19 0213_06122020_003657.mp4

Date
06/12/2020
W/O
833771
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00718
PipeID
P15183
Time
12:24 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7729
Sewer Name
ARTESIA-CERRITOS TRUNK
City
ARTESIA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_833771_TV19059_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0214
Downstream MH
19 0213
Dir. of Survey
Downstream
Length Surveyed
263.6 ft.
Total Length
263.6 ft.
Structural Index
3
Structural Quick
3J2I
Structural Rating
263
O&M Index
2
O&M Quick
2T00
O&M Rating
210
Overall Index
2
Overall Quick
Overall Rating
473
Pipe schematic from manhole 19 0214 to 19 0213
MH: 19 0214MH: 19 0213downstream0 ft. AMH - Upstream Manhole, Survey Begins - 19 02140 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start18.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"47.7 ft. FS - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES77.1 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 25% GREASE-LATERAL/OPEN87.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN106.4 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN129.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"139.5 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN182.8 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN193.3 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN228.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"261 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish261 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish263 ft. MGO - General Observation - ROACHES @ MH263.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish263.6 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN263.6 ft. AMH - Downstream Manhole, Survey Ends - 19 0213263.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish263.6 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (2)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

    47.7 ft. - Fracture Spiral, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (26)

DistanceCodeObservation
263.6DAE
263.6MGOCONN @ MH 9 O'CLOCK/UNKNOWN
261SSS
2CM
2SSS
0AMH19 0214
18.2TFC
47.7FS
0MWM
263MGOROACHES @ MH
106.4TFOPEN
263.6AMH19 0213
228.1TFC
2DAE
139.5TFOPEN
129.1TFC
263.6CM
0MWL
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
193.3TFOPEN
182.8TFOPEN
87.8TFOPEN
263.6MGOCONN @ MH 3 O'CLOCK/ACTIVE
77.1TFD25% GREASE-LATERAL/OPEN
261DAGS
2DAGS

Properties (7)

additional_info
SC411387
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-12T00:24:16-07:00
documentation
PROPIPE
is_lateral_inspection
false