Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2020, 08:42 AM
  • 05 1280_05 1279_06082020_015542.mp4

Date
06/08/2020
W/O
833683
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06494
Time
1:42 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7718
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_833683_TV05332_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1280
Downstream MH
05 1279
Dir. of Survey
Downstream
Length Surveyed
338.3 ft.
Total Length
338.3 ft.
Structural Index
3
Structural Quick
3L00
Structural Rating
201
O&M Index
2
O&M Quick
412M
O&M Rating
194
Overall Index
2
Overall Quick
Overall Rating
395
Pipe schematic from manhole 05 1280 to 05 1279
MH: 05 1280MH: 05 1279downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 12800 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start3.9 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start69.4 ft. RFJ - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YES70.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - BROKEN CAP82.8 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start90.1 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 4", 6" - 85% ROOTS/GREASE-LATERAL90.1 ft. RFC - Roots Fine Connection, from 08 to 10 o'clock90.1 ft. RFL - Roots Fine Lateral, at 10 o'clock - 10% ROOTS/GREASE90.1 ft. RBL - Roots Ball Lateral, at 10 o'clock, 60 %120.7 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN271.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"336 ft. DAGS - Deposits Attached Grease, 10 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish338 ft. MGO - General Observation - ROACHES @ MH338.3 ft. AMH - Downstream Manhole, Survey Ends - 05 1279338.3 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.3 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish338.3 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE

Observation photos (5)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    3.9 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YES

    69.4 ft. - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YES

  • Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    82.8 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Roots Fine Connection, from 08 to 10 o'clock

    90.1 ft. - Roots Fine Connection, from 08 to 10 o'clock

  • Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

    120.7 ft. - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN

Observations (22)

DistanceCodeObservation
336DAGS
120.7TBOPEN
90.1TFD85% ROOTS/GREASE-LATERAL
0MWL
90.1RFC
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
338.3AMH05 1279
82.8RFJ
338.3RFJ
90.1RFL10% ROOTS/GREASE
338.3CM
338.3MGOCONN @ MH 3 O'CLOCK/ACTIVE
2DAGS
3.9CM
0MWM
69.4RFJ
70.1TFCBROKEN CAP
0AMH05 1280
338MGOROACHES @ MH
271.9TFC
90.1RBL
0MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
SC411375
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-08T01:42:17-07:00
documentation
PRO PIPE
is_lateral_inspection
false