Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2020, 08:58 AM
  • 05 1277_05 1276_06082020_022355.mp4

Date
06/08/2020
W/O
833683
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00518
PipeID
P06490
Time
1:58 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7718
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_833683_TV05332_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1277
Downstream MH
05 1276
Dir. of Survey
Downstream
Length Surveyed
337.4 ft.
Total Length
337.4 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
332
O&M Index
2
O&M Quick
2400
O&M Rating
8
Overall Index
2
Overall Quick
Overall Rating
340
Pipe schematic from manhole 05 1277 to 05 1276
MH: 05 1277MH: 05 1276downstream0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCKACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 05 12770 ft. MWL - Water Level, 15 %of cross sectional area0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.1 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start65.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"68.6 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"99.6 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE265 ft. TBC - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"270 ft. TBC - Tap Break-In Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"335 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337.4 ft. AMH - Downstream Manhole, Survey Ends - 05 1276337.4 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish337.4 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE337.4 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (4)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    68.6 ft. - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE

    99.6 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 1" - ACTIVE

  • Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

    265 ft. - Tap Break-In Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"

Observations (17)

DistanceCodeObservation
337.4AMH05 1276
0MGOCONN @ MH 3 O'CLOCKACTIVE
0AMH05 1277
335SSS
337.4CM
7.1CM
0MWL
337.4MGOCONN @ MH 3 O'CLOCK/ACTIVE
265TBC
99.6TBIACTIVE
68.6TBC
0MWM
337.4MGOCONN @ MH 9 O'CLOCK/ACTIVE
270TBC
2SSS
65.6TFC
0MGOCONN @ MH 9 O'CLOCK/ACTIVE

Properties (7)

additional_info
SC411375
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-08T01:58:48-07:00
documentation
PRO PIPE
is_lateral_inspection
false