Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2020, 06:18 AM
  • 05 1269_05 1268_06042020_233112.mp4

Date
06/04/2020
W/O
833683
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00518
PipeID
P06481
Time
11:18 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7322
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_833683_TV05332_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1269
Downstream MH
05 1268
Dir. of Survey
Downstream
Length Surveyed
208.2 ft.
Total Length
208.2 ft.
Structural Index
3
Structural Quick
4F32
Structural Rating
224
O&M Index
2
O&M Quick
2G00
O&M Rating
84
Overall Index
3
Overall Quick
Overall Rating
308
Pipe schematic from manhole 05 1269 to 05 1268
MH: 05 1269MH: 05 1268downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 05 12692 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.5 ft. FM - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 4"36.6 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start87.1 ft. TB - Tap Break-In, at 02 o'clock, -, within 8 inches of joint: NO, 6" - OPEN110.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"114.5 ft. TBI - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - UNKNOWN187 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: NO, 6" - OPEN203.3 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish205.3 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish206 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish206 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish208.2 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE208.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1268

Observation photos (4)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

    4.5 ft. - Fracture Multiple, from 12 to 04 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    36.6 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - UNKNOWN

    114.5 ft. - Tap Break-In Intruding, at 10 o'clock, -, -, within 8 inches of joint: NO, 6", 2" - UNKNOWN

Observations (20)

DistanceCodeObservation
87.1TBOPEN
0MWM
208.2MGOCONN @ MH 3 O'CLOCK/ACTIVE
205.3DAGS
2DAGS
36.6FM
114.5TBIUNKNOWN
7TFC
187TBOPEN
4.5FM
110.5TFC
2CM
206SSS
0MWL
203.3FM
208.2AMH05 1268
0MGOCONN @ MH 9 O'CLOCK/ACTIVE
206CM
0AMH05 1269
2SSS

Properties (7)

additional_info
SC411311
custom_field_three
CRACKS MULTIPLE
custom_field_two
3
customer
1
datetime
2020-06-04T23:18:55-07:00
documentation
PRO PIPE
is_lateral_inspection
false