Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 5, 2020, 06:34 AM
  • 05 1268_05 1267_06052020_003242.mp4

Date
06/04/2020
W/O
833683
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00518
PipeID
P06480
Time
11:34 PM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7322
Sewer Name
SO HAWTHORNE-WARFIELD AV EXT TR, SECT 4
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
19
Purpose
Routine Assessment
Project
RFIR_WO_833683_TV05332_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
15 in.
Width
24 in.
Upstream MH
05 1268
Downstream MH
05 1267
Dir. of Survey
Downstream
Length Surveyed
132.2 ft.
Total Length
132.2 ft.
Structural Index
3
Structural Quick
4C3D
Structural Rating
218
O&M Index
2
O&M Quick
312D
O&M Rating
55
Overall Index
3
Overall Quick
Overall Rating
273
Pipe schematic from manhole 05 1268 to 05 1267
MH: 05 1268MH: 05 1267downstream0 ft. AMH - Upstream Manhole, Survey Begins - 05 12680 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. MWL - Water Level, 20 %of cross sectional area2 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start4.9 ft. FM - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES21.9 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start55.9 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"63.6 ft. TBD - Tap Break-In Defective, at 10 o'clock, -, , within 8 inches of joint: YES, 4", 6" - BROKEN/OPEN120.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"127.2 ft. FM - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish130 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish130 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish130.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish132.2 ft. AMH - Downstream Manhole, Survey Ends - 05 1267132.2 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE

Observation photos (3)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

    4.9 ft. - Fracture Multiple, from 09 to 12 o'clock, within 8 inches of joint: YES

  • Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    21.9 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (18)

DistanceCodeObservation
132.2AMH05 1267
4.9FM
130SSS
0AMH05 1268
21.9FM
63.6TBDBROKEN/OPEN
127.2FM
130.7DAGS
0MWM
2CM
130CM
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
2SSS
2DAGS
55.9TFC
132.2MGOCONN @ MH 9 O'CLOCK/ACTIVE
120.4TFC
0MWL

Properties (7)

additional_info
SC411311
custom_field_three
CRACKS MULTIPLE
custom_field_two
3
customer
1
datetime
2020-06-04T23:34:15-07:00
documentation
PRO PIPE
is_lateral_inspection
false