Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2020, 10:04 AM
  • 02 0032_02 0031 _06222020_031501.mp4

Date
06/22/2020
W/O
833685
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00234
PipeID
P03063
Time
3:04 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7736
Sewer Name
ARTESIA EXTENSION TRUNK
City
BELLFLOWER
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
39
Purpose
Routine Assessment
Project
RFIR_WO_833685_TV02341_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
18 in.
Width
10 in.
Upstream MH
02 0031
Downstream MH
02 0032
Dir. of Survey
Upstream
Length Surveyed
323.7 ft.
Total Length
323.7 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
320
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
320
Pipe schematic from manhole 02 0031 to 02 0032
MH: 02 0031MH: 02 0032upstream0 ft. AMH - Upstream Manhole, Survey Ends - 02 00320.1 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN0.2 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish0.7 ft. MGO - General Observation - ROACHES @ MH2.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish172.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"174.1 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"263.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"265.4 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"320.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start321.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start323.7 ft. MWL - Water Level, 15 %of cross sectional area323.7 ft. MWM - Water Mark, 20 %of cross sectional area323.7 ft. AMH - Downstream Manhole, Survey Begins - 02 0031

Observation photos (1)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    3.1 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

Observations (14)

DistanceCodeObservation
151.5TFC
0MWL
0MWM
2SSS
323MGOROACHES @ MH
60.5TFC
3.1CM
149.6TFC
323.7AMH02 0032
321SSS
0AMH02 0031
323.6MGOCONN @ MH 3 O'CLOCK/UNKNOWN
323.5CM
58.3TFC

Properties (7)

additional_info
SC411395
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-22T03:04:12-07:00
documentation
PROPIPE
is_lateral_inspection
false