- Date
- 06/22/2020
- W/O
- 833685
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00234
- PipeID
- P03032
- Time
- 1:20 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7736
- Sewer Name
- ARTESIA EXTENSION TRUNK
- City
- BELLFLOWER
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 02
- Page No.
- 38
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833685_TV02341_JUN2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 21 in.
- Width
- 15 in.
- Upstream MH
- 02 0006
- Downstream MH
- 02 0005A
- Dir. of Survey
- Downstream
- Length Surveyed
- 286.5 ft.
- Total Length
- 286.5 ft.
- Structural Index
- 3
- Structural Quick
- 4I34
- Structural Rating
- 332
- O&M Index
- 2
- O&M Quick
- 312J
- O&M Rating
- 122
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 454
Pipe schematic from manhole 02 0006 to 02 0005A Observation photos (4)

5.2 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

25.5 ft. - Fracture Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

194 ft. - Tap Break-In Defective, at 12 o'clock, -, , within 8 inches of joint: YES, 4", 6" - FRACTURED/BROKEN

250.4 ft. - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YES, Start