Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 8, 2020, 10:45 AM
  • 05 1484_05 2341_06082020_035801.mp4

Date
06/08/2020
W/O
833689
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00438
PipeID
P06710
Time
3:45 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7719
Sewer Name
EL NIDO TRUNK
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_833689_TV05300_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
24 in.
Upstream MH
05 1484
Downstream MH
05 2341
Dir. of Survey
Downstream
Length Surveyed
332.7 ft.
Total Length
332.7 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
332
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
332
Pipe schematic from manhole 05 1484 to 05 2341
MH: 05 1484MH: 05 2341downstream0 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/UNKNOWN0 ft. MGO - General Observation - ROACHES @ MH0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/UNKNOWN0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 05 14840 ft. MWM - Water Mark, 25 %of cross sectional area2 ft. MGO - General Observation - 65% MAG COAT2.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.6 ft. CS - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES49.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"81.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN126.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN185.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN187.7 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 4", 6"198.8 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"245.6 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN277.8 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 6" - OPEN332 ft. MGO - General Observation - ROACHES @ MH332.7 ft. AMH - Downstream Manhole, Survey Ends - 05 2341332.7 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish332.7 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE332.7 ft. MGO - General Observation - CONN @ MH 12 O'CLOCK/OPEN332.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.7 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

    4.6 ft. - Crack Spiral, from 03 to 05 o'clock, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
332.7AMH05 2341
0MGOCONN @ MH 9 O'CLOCK/UNKNOWN
126.2TFOPEN
332.7SSS
49.9TFC
332.7MGOCONN @ MH 9 O'CLOCK/ACTIVE
0MGOROACHES @ MH
187.7TFA
332MGOROACHES @ MH
2.7SAP
185.9TFOPEN
198.8TFC
277.8TFOPEN
2MGO65% MAG COAT
245.6TFOPEN
81.2TFOPEN
0MGOCONN @ MH 3 O'CLOCK/UNKNOWN
2.7SSS
332.7MGOCONN @ MH 12 O'CLOCK/OPEN
0MWL
0AMH05 1484
332.7SAP
4.6CS
0MWM

Properties (7)

additional_info
SC411376
custom_field_three
AGGREGATE PROJECTING/ SURFACE SPALLING
custom_field_two
2
customer
1
datetime
2020-06-08T03:45:38-07:00
documentation
PROPIPE
is_lateral_inspection
false