Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 9, 2020, 07:59 AM
  • 05 1480_05 1479_06092020_011640.mp4

Date
06/09/2020
W/O
833689
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00438
PipeID
P06704
Time
12:59 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7721
Sewer Name
EL NIDO TRUNK
City
REDONDO BEACH
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_833689_TV05300_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
27 in.
Upstream MH
05 1479
Downstream MH
05 1480
Dir. of Survey
Upstream
Length Surveyed
322.8 ft.
Total Length
322.8 ft.
Structural Index
3
Structural Quick
3L2L
Structural Rating
320
O&M Index
2
O&M Quick
2200
O&M Rating
4
Overall Index
2
Overall Quick
Overall Rating
324
Pipe schematic from manhole 05 1479 to 05 1480
MH: 05 1479MH: 05 1480upstream0 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0 ft. AMH - Upstream Manhole, Survey Ends - 05 14800 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/CAPPED0 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish0.8 ft. MGO - General Observation - ROACHES @ MH88.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"164.5 ft. TFC - Tap Factory Made Capped, at 12 o'clock, -, within 8 inches of joint: NO, 6"219.9 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES219.9 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: NO, 6"241.8 ft. DAR - Deposits Attached Ragging, 5 %of cross sectional area, from 11 to 01 o'clock, , within 8 inches of joint: YES241.8 ft. TFA - Tap Factory Made Active, at 12 o'clock, -, within 8 inches of joint: YES, 4", 6"320.6 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start320.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start320.8 ft. MGO - General Observation - 70% MAG COAT322.8 ft. MWL - Water Level, 15 %of cross sectional area322.8 ft. AMH - Downstream Manhole, Survey Begins - 05 1479322.8 ft. MWM - Water Mark, 20 %of cross sectional area

Observation photos (2)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.2 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (17)

DistanceCodeObservation
322.8SSS
322.8AMH05 1480
322.8MGOCONN @ MH 9 O'CLOCK/CAPPED
0MWL
158.3TFC
322MGOROACHES @ MH
81DAR
102.9DAGS
234TFA
81TFA
0AMH05 1479
0MWM
2MGO70% MAG COAT
102.9TFA
2.1SAP
322.8SAP
2.2SSS

Properties (7)

additional_info
SC411379
custom_field_three
AGGREGATE PROJECTING/ SURFACE SPALLING
custom_field_two
2
customer
1
datetime
2020-06-09T00:59:29-07:00
documentation
PROPIPE
is_lateral_inspection
false