- Date
- 06/09/2020
- W/O
- 833689
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00438
- PipeID
- P06700
- Time
- 2:59 AM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7721
- Sewer Name
- EL NIDO TRUNK
- City
- REDONDO BEACH
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- RFIR_WO_833689_TV05300_JUN2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 12 in.
- Width
- 27 in.
- Upstream MH
- 05 1476
- Downstream MH
- 05 1475
- Dir. of Survey
- Downstream
- Length Surveyed
- 319.6 ft.
- Total Length
- 319.6 ft.
- Structural Index
- 3
- Structural Quick
- 3K2J
- Structural Rating
- 300
- O&M Index
- 0
- O&M Quick
- 0000
- O&M Rating
- 0
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 300
Pipe schematic from manhole 05 1476 to 05 1475 Observation photos (3)

11.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

32.9 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

319.2 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: NO, 6"