- Date
- 08/07/2020
- W/O
- 0838887
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z01180
- PipeID
- P00836
- Time
- 1:17 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1513
- Sewer Name
- G JOINT OUTFALL G - UNIT 8
- City
- COMPTON
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 01
- Page No.
- 17
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200804MDM_JOINT_OUTFALL_G_UNIT_8
- Material
- RCP-CTL
- Shape
- Circular
- Height
- 36 in.
- Upstream MH
- G 0155
- Downstream MH
- G 0154
- Dir. of Survey
- Downstream
- Length Surveyed
- 390.7 ft.
- Total Length
- 390.7 ft.
- Structural Index
- 0
- Structural Quick
- 0000
- Structural Rating
- 0
- O&M Index
- 3
- O&M Quick
- 4121
- O&M Rating
- 6
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 6
Pipe schematic from manhole G 0155 to G 0154 Observation photos (8)

2 ft. - General Observation - MAG COAT 98% START

2 ft. - General Observation - SLIME GREASE COAT ON MAG COAT

2 ft. - General Observation - TILES 100% IN PLACE UNDER MAG COAT

82.9 ft. - General Observation - TILES IN PLACE UNDER MAG COAT

160.4 ft. - Water Mark, 60 %of cross sectional area

250.9 ft. - General Photograph - MAG COAT SLIME GREASE COVERING

286.7 ft. - General Observation - TILES IN PLACE

293.3 ft. - General Observation - 80% MAG COAT