Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 6, 2020, 09:48 AM
  • 19 0037_19 0036_862020_031936.mp4

Date
08/06/2020
W/O
0843524
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00725
PipeID
P15067
Time
2:48 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1511
Sewer Name
19 FULLERTON ROAD TRUNK
City
HAWAIIAN GARDENS
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
09
Purpose
Capital Improvement Program Assesment
Project
20200806MDM_FULLERTON_ROAD_TRUNK
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Upstream MH
19 0037
Downstream MH
19 0036
Dir. of Survey
Downstream
Length Surveyed
330.9 ft.
Total Length
330.9 ft.
Structural Index
3
Structural Quick
413E
Structural Rating
158
O&M Index
2
O&M Quick
3326
O&M Rating
21
Overall Index
3
Overall Quick
Overall Rating
179
Pipe schematic from manhole 19 0037 to 19 0036
MH: 19 0037MH: 19 0036downstream0 ft. AMH - Upstream Manhole, Survey Begins - 3:15AM0 ft. MWM - Water Mark, 20 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area7.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - HAIRLINE7.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES7.5 ft. FC - Fracture Circumferential, from 07 to 09 o'clock, within 8 inches of joint: YES - HAIRLINE22.1 ft. MGO - General Observation - 2% MINERIAL DEPOSIT22.1 ft. FC - Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES - SLIGHT33.2 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped34.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 04 o'clock, , within 8 inches of joint: YES39.7 ft. FC - Fracture Circumferential, from 01 to 03 o'clock, within 8 inches of joint: YES - H44.6 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL59.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H59.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H64.8 ft. FC - Fracture Circumferential, from 08 to 12 o'clock, within 8 inches of joint: YES - SL64.8 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H69.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H80.1 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES80.1 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H81.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6" - Capped82.6 ft. FL - Fracture Longitudinal, at 04 o'clock, within 8 inches of joint: YES - H82.6 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 10 to 04 o'clock, , within 8 inches of joint: YES87.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H92.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H92.6 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES - SL107.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H107.5 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H107.5 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES122.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - 5% OR LESS AT JOINTS SPORATIC122.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H127.9 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H132.1 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES132.9 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H134 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped135.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL139.2 ft. DAE - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 02 o'clock, , within 8 inches of joint: YES140.7 ft. FC - Fracture Circumferential, from 03 to 04 o'clock, within 8 inches of joint: YES - H150.4 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H150.4 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H155.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H155.7 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - H165.8 ft. FC - Fracture Circumferential, from 07 to 10 o'clock, within 8 inches of joint: YES - H165.8 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES, 6ft - H170.7 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES170.7 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H180.9 ft. FC - Fracture Circumferential, from 01 to 04 o'clock, within 8 inches of joint: YES - H181.1 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H182.3 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped183.8 ft. FC - Fracture Circumferential, from 09 to 10 o'clock, within 8 inches of joint: NO - H183.8 ft. FC - Fracture Circumferential, from 01 to 02 o'clock, within 8 inches of joint: YES - H188.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H188.5 ft. FC - Fracture Circumferential, from 10 to 11 o'clock, within 8 inches of joint: YES193.2 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H213.3 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H223.4 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H228.5 ft. FC - Fracture Circumferential, from 12 to 01 o'clock, within 8 inches of joint: YES - SL229.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped231.4 ft. FC - Fracture Circumferential, from 09 to 12 o'clock, within 8 inches of joint: YES - SL231.4 ft. FC - Fracture Circumferential, from 08 to 09 o'clock, within 8 inches of joint: YES - H236.3 ft. FC - Fracture Circumferential, from 02 to 05 o'clock, within 8 inches of joint: YES - SL236.5 ft. FC - Fracture Circumferential, from 11 to 01 o'clock, within 8 inches of joint: YES - H236.5 ft. FC - Fracture Circumferential, from 07 to 11 o'clock, within 8 inches of joint: YES - SL241.4 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - H261.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H271.6 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL276.5 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H281.5 ft. FL - Fracture Longitudinal, at 03 o'clock, within 8 inches of joint: YES - H282.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped284.3 ft. FC - Fracture Circumferential, from 08 to 11 o'clock, within 8 inches of joint: YES - SL289.1 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H289.1 ft. FL - Fracture Longitudinal, at 01 o'clock, within 8 inches of joint: YES - H294.4 ft. FL - Fracture Longitudinal, at 11 o'clock, within 8 inches of joint: YES - H299.3 ft. FC - Fracture Circumferential, from 12 to 03 o'clock, within 8 inches of joint: YES - SL299.3 ft. FL - Fracture Longitudinal, at 09 o'clock, within 8 inches of joint: YES - H304.2 ft. FC - Fracture Circumferential, from 02 to 04 o'clock, within 8 inches of joint: YES - SL304.2 ft. FC - Fracture Circumferential, from 08 to 10 o'clock, within 8 inches of joint: YES - H309.5 ft. FL - Fracture Longitudinal, at 12 o'clock, within 8 inches of joint: YES - H314.7 ft. FL - Fracture Longitudinal, at 02 o'clock, within 8 inches of joint: YES - H314.7 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H319.3 ft. FM - Fracture Multiple, from 06 to 05 o'clock, within 8 inches of joint: YES - SLIGHT324.6 ft. FL - Fracture Longitudinal, at 10 o'clock, within 8 inches of joint: YES - H330.2 ft. MGO - General Observation - MH CONN 9:00 ACTIVE330.2 ft. MGO - General Observation - MH CONN 3:00 ACTIVE330.2 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Finish - 5% OR LESS THROUGHOUT REACH SPORATIC330.9 ft. AMH - Downstream Manhole, Survey Ends - 4:05AM

Observation photos (6)

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 04 o'clock,  , within 8 inches of joint: YES

    34.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 12 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 10 to 04 o'clock,  , within 8 inches of joint: YES

    82.6 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 10 to 04 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock,  , within 8 inches of joint: YES, Start - 5% OR LESS AT JOINTS SPORATIC

    122.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start - 5% OR LESS AT JOINTS SPORATIC

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 11 o'clock,  , within 8 inches of joint: YES

    132.1 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 11 o'clock, , within 8 inches of joint: YES

  • Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 02 o'clock,  , within 8 inches of joint: YES

    139.2 ft. - Deposits Attached Encrustation, 15 %of cross sectional area, from 08 to 02 o'clock, , within 8 inches of joint: YES

  • Fracture Multiple, from 06 to 05 o'clock, within 8 inches of joint: YES - SLIGHT

    319.3 ft. - Fracture Multiple, from 06 to 05 o'clock, within 8 inches of joint: YES - SLIGHT

Observations (85)

DistanceCodeObservation
282.6TFCCapped
188.5FLH
294.4FLH
223.4FLH
122.7DAE5% OR LESS AT JOINTS SPORATIC
64.8FCSL
82.6FLH
289.1FLH
213.3FLH
188.5FC
92.6FLH
193.2FLH
228.5FCSL
180.9FCH
330.2MGOMH CONN 9:00 ACTIVE
22.1MGO2% MINERIAL DEPOSIT
122.7FLH
165.8FCH
80.1DAE
132.1DAE
170.7DAE
299.3FCSL
127.9FLH
140.7FCH
261.5FLH
314.7FLH
80.1FLH
236.5FCH
155.7FCH
276.5FLH
241.4FCH
69.7FLH
182.3TFCCapped
150.4FLH
236.5FCSL
0AMH3:15AM
107.5FLH
314.7FLH
330.2MGOMH CONN 3:00 ACTIVE
155.7FCH
0MWM
324.6FLH
87.7FLH
271.6FCSL
64.8FLH
59.8FLH
330.2DAE5% OR LESS THROUGHOUT REACH SPORATIC
304.2FCSL
236.3FCSL
82.6DAE
7.5FLHAIRLINE
319.3FMSLIGHT
165.8FLH
330.9AMH4:05AM
81.2TFCCapped
229.9TFCCapped
289.1FLH
107.5FCH
132.9FLH
134TFCCapped
231.4FCSL
231.4FCH
0MWL
22.1FCSLIGHT
150.4FLH
39.7FCH
181.1FLH
139.2DAE
7.5DAE
299.3FLH
34.7DAE
33.2TFCCapped
7.5FCHAIRLINE
170.7FCH
135.4FCSL
107.5DAE
284.3FCSL
59.8FLH
183.8FCH
281.5FLH
304.2FCH
44.6FCSL
183.8FCH
92.6FCSL
309.5FLH

Properties (6)

custom_field_three
SLIGHT & HAIRLINE FRACTURES
custom_field_two
3
customer
LACSD
datetime
2020-08-06T02:48:06-07:00
documentation
MARTIN,SHADLER,BARR
is_lateral_inspection
false