- Date
- 08/10/2020
- W/O
- 0836915
- Weather
- Dry
- Operator/Surveyor
- MARTIN
- Sewer ID
- Z00152
- PipeID
- P26735
- Time
- 3:10 AM
- Certificate
- U-1014-06022543
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- H1523
- Sewer Name
- D JOINT OUTFALL D - UNIT 2B
- City
- GARDENA
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 05
- Page No.
- 24
- Purpose
- Capital Improvement Program Assesment
- Project
- 20200810MDM_JOINT_OUTFALL_D_UNIT_2B
- Material
- Reinforced Concrete Pipe
- Shape
- Circular
- Height
- 57 in.
- Upstream MH
- 5 GARDENA
- Downstream MH
- D 0051A
- Dir. of Survey
- Downstream
- Length Surveyed
- 8.6 ft.
- Total Length
- 8.6 ft.
- Structural Index
- 5
- Structural Quick
- 5241
- Structural Rating
- 14
- O&M Index
- 5
- O&M Quick
- 5100
- O&M Rating
- 5
- Overall Index
- 5
- Overall Quick
- —
- Overall Rating
- 19
Pipe schematic from manhole 5 GARDENA to D 0051A Observation photos (5)

2 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Start - LONG & CIRCUM REBAR BROKEN

2 ft. - Surface Aggregate Missing, from 10 to 02 o'clock, within 8 inches of joint: YES, Start - SEVERE AGG

4 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO - CIRCUM REBAR MISSING

8 ft. - Surface Reinforcement Corroded, from 10 to 02 o'clock, within 8 inches of joint: NO, Finish - LONG & CIRCUM REBAR CORRODED MISSING

8.6 ft. - Survey Abandoned - DOWNLEG UPSTREAM SIPHON