Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Aug 10, 2020, 08:30 AM
  • D 0051A_D 0051_8102020_025711.mp4

Date
08/10/2020
W/O
0836915
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00152
PipeID
P09951
Time
1:30 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1523
Sewer Name
D JOINT OUTFALL D - UNIT 2B
City
GARDENA
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 05
Page No.
24
Purpose
Capital Improvement Program Assesment
Project
20200810MDM_JOINT_OUTFALL_D_UNIT_2B
Material
Reinforced Concrete Pipe
Shape
Circular
Height
57 in.
Upstream MH
D 0051A
Downstream MH
D 0051
Dir. of Survey
Downstream
Length Surveyed
2.5 ft.
Total Length
2.5 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole D 0051A to D 0051
MH: D 0051AMH: D 0051downstream0 ft. MWM - Water Mark, 0 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 2:55AM0 ft. MWL - Water Level, 0 %of cross sectional area2 ft. MGO - General Observation - VALUE STRUCTURE UNDER 2" OF WATER2.5 ft. MSA - Survey Abandoned - DOWNLEG UPTREAM SIPHON

Observation photos (2)

  • General Observation - VALUE STRUCTURE UNDER 2" OF WATER

    2 ft. - General Observation - VALUE STRUCTURE UNDER 2" OF WATER

  • Survey Abandoned - DOWNLEG UPTREAM SIPHON

    2.5 ft. - Survey Abandoned - DOWNLEG UPTREAM SIPHON

Observations (5)

DistanceCodeObservation
0MWM
2.5MSADOWNLEG UPTREAM SIPHON
0AMH2:55AM
0MWL
2MGOVALUE STRUCTURE UNDER 2" OF WATER

Properties (8)

additional_info
DOWNLEG UPSTREAM SIPHON
custom_field_three
LONG & CIRCUM REBAR CORRODED(UPLEG)
custom_field_two
2
customer
LACSD
datetime
2020-08-10T01:30:35-07:00
documentation
MARTIN,OLIVER 111,BARR
is_lateral_inspection
false
year_laid
19970821