Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2015, 11:32 AM
  • 22 0751_22 0750_20151204_035525.mp4

Date
12/04/2015
W/O
536652
Weather
Dry
Operator/Surveyor
J. HARTOOG
Sewer ID
Z00821
PipeID
P17108
Time
3:32 AM
Certificate
U-507-03-3386
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2878
Sewer Name
22 PUDDINGSTONE TRUNK, SECTS 1&2
City
SAN DIMAS, CA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
23
Purpose
V
Project
WO_536652_TV22057_NOV2015
Sewer Type
SIPHON
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
22 0750
Downstream MH
22 0751
Dir. of Survey
Upstream
Length Surveyed
262.2 ft.
Total Length
262.2 ft.
Structural Index
3
Structural Quick
3I00
Structural Rating
156
O&M Index
2
O&M Quick
3122
O&M Rating
7
Overall Index
3
Overall Quick
Overall Rating
163
Pipe schematic from manhole 22 0750 to 22 0751
MH: 22 0750MH: 22 0751upstream0 ft. MSA - Survey Abandoned - REVERSAL COMPLETE0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish0.1 ft. MGO - General Observation - REVERSAL COMPLETE2.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish7.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"59 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"104.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"156.5 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"209.1 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"212.9 ft. RMJ - Roots Medium Joint, from 01 to 05 o'clock, 25 %, within 8 inches of joint: YESR253.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"258.7 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start260.2 ft. MGO - General Observation - MAGNESIUM H.O. START 80%262.2 ft. MGO - Reversal Inspection262.2 ft. MWM - Water Mark, 45 %of cross sectional area262.2 ft. MWL - Water Level, 15 %of cross sectional area262.2 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 2262.2 ft. AMH - Downstream Manhole, Survey Begins - 22 0750

Observation photos (1)

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 2

    0 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start - 2

Observations (18)

DistanceCodeObservation
254.3TFC
0MGO
53.1TFC
8.9TFC
0MWM
0MWL
262.2MSAREVERSAL COMPLETE
203.2TFC
2MGOMAGNESIUM H.O. START 80%
262.2DAGS
260SAV
3.5DAGS
0SAV2
262.1MGOREVERSAL COMPLETE
0AMH22 0750
49.3RMJ
157.7TFC
105.7TFC

Properties (6)

additional_info
SC205646
custom_field_two
0
customer
LACSD
datetime
2015-12-04T03:32:51-08:00
documentation
PRO-PIPE
is_lateral_inspection
false