- Date
- 12/03/2015
- W/O
- 536652
- Weather
- Dry
- Operator/Surveyor
- J. HARTOOG
- Sewer ID
- Z00821
- PipeID
- P17111
- Time
- 11:31 PM
- Certificate
- U-507-03-3386
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K2878
- Sewer Name
- 22 PUDDINGSTONE TRUNK, SECTS 1&2
- City
- SAN DIMAS, CA
- Loc. details
- Easement/Right of Way
- Location Code
- D
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 23
- Purpose
- Routine Assessment
- Project
- WO_536652_TV22057_NOV2015
- Sewer Type
- GRAVITY
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Upstream MH
- 22 0754
- Downstream MH
- 22 0753
- Dir. of Survey
- Downstream
- Length Surveyed
- 269.1 ft.
- Total Length
- 269.1 ft.
- Structural Index
- 3
- Structural Quick
- 3J00
- Structural Rating
- 159
- O&M Index
- 2
- O&M Quick
- 2J00
- O&M Rating
- 106
- Overall Index
- 3
- Overall Quick
- —
- Overall Rating
- 265
Pipe schematic from manhole 22 0754 to 22 0753 Observation photos (2)

2 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

69.2 ft. - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: YES, 6" - W/ SEVERELY LARGE OFFSET INSIDE LATERAL