Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 4, 2015, 11:07 AM
  • 30 0141_30 0140_20151204_042305_.mpg

Date
12/04/2015
W/O
536532
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00878
PipeID
P17846
Time
3:07 AM
Certificate
12345
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2957
Sewer Name
30 SOUTH BAY CITIES MAIN TRUNK
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
07
Purpose
Routine Assessment
Project
WO_536532_TV30036_NOV2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Other
Height
18 in.
Upstream MH
30 0141
Downstream MH
30 0140
Dir. of Survey
Downstream
Length Surveyed
249.6 ft.
Total Length
249.6 ft.
Structural Index
2
Structural Quick
2100
Structural Rating
2
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
2
Overall Quick
Overall Rating
2
Pipe schematic from manhole 30 0141 to 30 0140
MH: 30 0141MH: 30 0140downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 30 01410 ft. MWL - Water Level, 20 %of cross sectional area60.8 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6", 6"94.2 ft. CS - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES135.9 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"204.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4"210.9 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"242 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"249.6 ft. AMH - Downstream Manhole, Survey Ends - 30 0140

Observation photos (5)

  • Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

    94.2 ft. - Crack Spiral, from 02 to 03 o'clock, within 8 inches of joint: YES

  • Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    135.9 ft. - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6"

  • Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    204.3 ft. - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

    210.9 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 4"

  • Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

    242 ft. - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6"

Observations (10)

DistanceCodeObservation
242TF
0MWM
0AMH30 0141
135.9TFC
249.6AMH30 0140
210.9TF
94.2CS
204.3TB
0MWL
60.8TFC

Properties (6)

additional_info
SC205554
custom_field_two
4
customer
LACSD
datetime
2015-12-04T03:07:53-08:00
documentation
PRO PIPE
is_lateral_inspection
false