Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Dec 7, 2015, 11:51 AM
  • 30 0134_30 0133_20151207_050607_.mp4

Date
12/07/2015
W/O
536532
Weather
Dry
Operator/Surveyor
M.MARTINEZ
Sewer ID
Z00878
PipeID
P17839
Time
3:51 AM
Certificate
12345
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K2958
Sewer Name
30 SOUTH BAY CITIES MAIN TRUNK
City
REDONDO BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 30
Page No.
07
Purpose
Routine Assessment
Project
WO_536532_TV30036_NOV2015
Sewer Type
GRAVITY
Material
Vitrified Clay Pipe
Shape
Other
Height
18 in.
Upstream MH
30 0133
Downstream MH
30 0134
Dir. of Survey
Upstream
Length Surveyed
175.4 ft.
Total Length
175.4 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
3
O&M Quick
3F11
O&M Rating
100
Overall Index
3
Overall Quick
Overall Rating
100
Pipe schematic from manhole 30 0133 to 30 0134
MH: 30 0133MH: 30 0134upstream0 ft. AMH - Upstream Manhole, Survey Ends - 30 01340.9 ft. MGO - General Observation - CONNECTION AT MANHOLE1.9 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish60.1 ft. TB - Tap Break-In, at 11 o'clock, -, within 8 inches of joint: YES, 6"66.1 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"74.5 ft. RFJ - Roots Fine Joint, from 03 to 05 o'clock, within 8 inches of joint: YESR130.4 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"142.3 ft. TFC - Tap Factory Made Capped, at 01 o'clock, -, within 8 inches of joint: YES, 6"156.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"166.3 ft. TFC - Tap Factory Made Capped, at 11 o'clock, -, within 8 inches of joint: YES, 6"168.3 ft. DAGS - Deposits Attached Grease, 20 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start175.4 ft. MWL - Water Level, 20 %of cross sectional area175.4 ft. MWM - Water Mark, 45 %of cross sectional area175.4 ft. AMH - Downstream Manhole, Survey Begins - 30 0133

Observations (14)

DistanceCodeObservation
109.3TFC
175.4AMH30 0134
174.5MGOCONNECTION AT MANHOLE
19.1TFC
115.3TB
7.1DAGS
0MWL
33.1TFC
0MWM
0AMH30 0133
45TFC
173.5DAGS
9.1TFC
100.9RFJ

Properties (6)

additional_info
SC205555
custom_field_two
4
customer
LACSD
datetime
2015-12-07T03:51:12-08:00
documentation
PRO PIPE
is_lateral_inspection
false