Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 1, 2020, 09:54 AM
  • 18 0919_18 0918_07012020_030015.mp4

Date
07/01/2020
W/O
833687
Weather
Dry
Operator/Surveyor
EN. RUIZ
Sewer ID
Z00709
PipeID
P14771
Time
2:54 AM
Certificate
U-116-07001919
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7772
Sewer Name
SO WHITTIER OUTFALL RLF TR, SECTS 1,2A,2B,2C,&3
City
S WHITTIER
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
20
Purpose
Routine Assessment
Project
RFIR_WO_833687_TV18184_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
15 in.
Width
15 in.
Upstream MH
18 0919
Downstream MH
18 0918
Dir. of Survey
Downstream
Length Surveyed
15.3 ft.
Total Length
15.3 ft.
Structural Index
3
Structural Quick
3222
Structural Rating
10
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
10
Pipe schematic from manhole 18 0919 to 18 0918
MH: 18 0919MH: 18 0918downstream0 ft. AMH - Upstream Manhole, Survey Begins - 18 09190 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - CONNECTION AT MH, 3 O'CLOCK0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MGO - General Observation - COCKROACHES IN MH2.1 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start2.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start14.2 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Finish14.2 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Finish15.3 ft. AMH - Downstream Manhole, Survey Ends - 18 091815.3 ft. MGO - General Observation - COCKROACHES IN MH

Observation photos (4)

  • General Observation - COCKROACHES IN MH

    0 ft. - General Observation - COCKROACHES IN MH

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: NO, Start

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: NO, Start

  • General Observation - COCKROACHES IN MH

    15.3 ft. - General Observation - COCKROACHES IN MH

Observations (11)

DistanceCodeObservation
0AMH18 0919
14.2SAP
15.3AMH18 0918
0MWL
2.1SSS
15.3MGOCOCKROACHES IN MH
0MGOCONNECTION AT MH, 3 O'CLOCK
2.1SAP
14.2SSS
0MWM
0MGOCOCKROACHES IN MH

Properties (7)

additional_info
SC427457
custom_field_three
SURFACE AGGREGATE, SPALLING
custom_field_two
3
customer
1
datetime
2020-07-01T02:54:25-07:00
documentation
PRO PIPE
is_lateral_inspection
false