Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 31, 2020, 04:26 PM
  • 15 0434_15 0433_7312020_095622.mp4

Date
07/31/2020
W/O
0828810
Weather
Dry
Operator/Surveyor
SANTIAGO OBREGON
Sewer ID
Z00608
PipeID
P12361
Time
9:26 AM
Certificate
U-1014-0622541
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1507
Sewer Name
15 HILL DRIVE EXTENSION TRUNK, LINE "A"
City
ROSEMEAD
Loc. details
Yard
Location Code
Y
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
26
Purpose
Routine Assessment
Project
20200731SHO_HILL_DRIVE_EXTENSION_TRUNK_LINE_A
Material
Vitrified Clay Pipe
Shape
Circular
Height
8 in.
Upstream MH
15 0434
Downstream MH
15 0433
Dir. of Survey
Downstream
Length Surveyed
229.6 ft.
Total Length
229.6 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
1
O&M Quick
1200
O&M Rating
2
Overall Index
1
Overall Quick
Overall Rating
2
Pipe schematic from manhole 15 0434 to 15 0433
MH: 15 0434MH: 15 0433downstream0 ft. MWM - Water Mark, 35 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - MH 043450.2 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: YES, 4"129.9 ft. TF - Tap Factory Made, at 12 o'clock, -, within 8 inches of joint: NO, 4"158.9 ft. RFJ - Roots Fine Joint, from 09 to 03 o'clock, within 8 inches of joint: YESR172.3 ft. RFJ - Roots Fine Joint, from 02 to 03 o'clock, within 8 inches of joint: YESR229.6 ft. AMH - Downstream Manhole, Survey Ends - MH 433

Observations (8)

DistanceCodeObservation
158.9RFJ
0MWM
129.9TF
0MWL
0AMHMH 0434
229.6AMHMH 433
50.2TF
172.3RFJ

Properties (5)

custom_field_two
4
customer
LACSD
datetime
2020-07-31T09:26:39-07:00
documentation
OBREGON, IGNACIO, RUVALCABA, CASTILLO
is_lateral_inspection
false