Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2020, 09:52 AM
  • 02 1420_02 1419 _05042020_025702.mp4

Date
05/04/2020
W/O
SC411149
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02991
Time
2:52 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7590
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
COMMERCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_829370_TV02220_MAY2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
02 1419
Downstream MH
02 1420
Dir. of Survey
Upstream
Length Surveyed
2.1 ft.
Total Length
2.1 ft.
Structural Index
3
Structural Quick
3100
Structural Rating
3
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
3
Pipe schematic from manhole 02 1419 to 02 1420
MH: 02 1419MH: 02 1420upstream0 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH0 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES2.1 ft. MWL - Water Level, 15 %of cross sectional area2.1 ft. AMH - Downstream Manhole, Survey Begins - 02 14192.1 ft. MWM - Water Mark, 40 %of cross sectional area

Observation photos (1)

  • Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH

    2.1 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH

Observations (5)

DistanceCodeObservation
2.1MSAVIEW OF U/S SIPHON FROM THE D/S MH
0MWL
0AMH02 1419
0MWM
2.1SAV

Properties (6)

additional_info
SC411149
custom_field_two
2
customer
LACSD
datetime
2020-05-04T02:52:49-07:00
documentation
PROPIPE
is_lateral_inspection
false