Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 4, 2020, 09:29 AM
  • 02 1420_02 1419 _05042020_023523.mp4

Date
05/04/2020
W/O
SC411149
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02991
Time
2:29 AM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7590
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
COMMERCE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
17
Purpose
Routine Assessment
Project
RFIR_WO_829370_TV02220_MAY2020
Sewer Type
Siphon
Material
Reinforced Concrete Pipe
Shape
Circular
Height
54 in.
Width
54 in.
Upstream MH
02 1420
Downstream MH
02 1419
Dir. of Survey
Downstream
Length Surveyed
11.7 ft.
Total Length
11.7 ft.
Structural Index
4
Structural Quick
5132
Structural Rating
11
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
11
Pipe schematic from manhole 02 1420 to 02 1419
MH: 02 1420MH: 02 1419downstream0 ft. MWM - Water Mark, 40 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 14202.1 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start4.6 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"5.1 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start11.7 ft. SRV - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Finish11.7 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish11.7 ft. MSA - Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.1 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

    5.1 ft. - Surface Reinforcement Visible, from 09 to 03 o'clock, within 8 inches of joint: YES, Start

  • Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH

    11.7 ft. - Survey Abandoned - VIEW OF U/S SIPHON FROM THE D/S MH

Observations (9)

DistanceCodeObservation
0MWM
11.7SRV
5.1SRV
4.6TF
11.7SAP
2.1SAP
0MWL
11.7MSAVIEW OF U/S SIPHON FROM THE D/S MH
0AMH02 1420

Properties (6)

additional_info
SC411149
custom_field_two
2
customer
LACSD
datetime
2020-05-04T02:29:07-07:00
documentation
PROPIPE
is_lateral_inspection
false