Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0May 5, 2020, 05:16 AM
  • 02 1399_02 1398 _05042020_234733.mp4

Date
05/04/2020
W/O
SC411149
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00349
PipeID
P02970
Time
10:16 PM
Certificate
U-508-7069
System Owner
LACSD
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7592
Sewer Name
02 DISTRICT #2 INTERCEPTOR TRUNK
City
BELL GARDENS
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 02
Page No.
23
Purpose
Routine Assessment
Project
RFIR_WO_829370_TV02220_MAY2020
Sewer Type
Gravity
Material
Reinforced Concrete Pipe
Shape
Circular
Height
48 in.
Width
48 in.
Upstream MH
02 1399
Downstream MH
02 1398
Dir. of Survey
Downstream
Length Surveyed
951.8 ft.
Total Length
951.8 ft.
Structural Index
4
Structural Quick
5e3e
Structural Rating
1520
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
4
Overall Quick
Overall Rating
1520
Pipe schematic from manhole 02 1399 to 02 1398
MH: 02 1399MH: 02 1398downstream0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 02 13990 ft. MWM - Water Mark, 35 %of cross sectional area2.6 ft. MGO - General Observation - MAG COAT2.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start39 ft. SMW - Surface Missing Wall, from 07 to 10 o'clock, within 8 inches of joint: YES342.9 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"649 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"757.3 ft. TF - Tap Factory Made, at 02 o'clock, -, within 8 inches of joint: NO, 6"946.3 ft. TFA - Tap Factory Made Active, at 02 o'clock, -, within 8 inches of joint: NO, 6", 6"951.8 ft. SRV - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish951.8 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish951.8 ft. AMH - Downstream Manhole, Survey Ends - 02 1398

Observation photos (3)

  • Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.8 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    8 ft. - Surface Reinforcement Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

  • Surface Missing Wall, from 07 to 10 o'clock, within 8 inches of joint: YES

    39 ft. - Surface Missing Wall, from 07 to 10 o'clock, within 8 inches of joint: YES

Observations (14)

DistanceCodeObservation
39SMW
946.3TFA
0MWL
2.6MGOMAG COAT
0AMH02 1399
0MWM
951.8SRV
951.8SAP
2.8SAP
649TF
757.3TF
8SRV
342.9TF
951.8AMH02 1398

Properties (6)

additional_info
SC411150
custom_field_two
1
customer
LACSD
datetime
2020-05-04T22:16:16-07:00
documentation
PROPIPE
is_lateral_inspection
false