- Date
- 06/11/2020
- W/O
- 833528
- Weather
- Dry
- Operator/Surveyor
- B.FUGATE
- Sewer ID
- Z00718
- PipeID
- P26795
- Time
- 11:45 PM
- Certificate
- U-508-7069
- System Owner
- 1
- Date Cleaned
- —
- Pre-Cleaning
- No Pre-Cleaning
- Media Label
- K7728
- Sewer Name
- ARTESIA-CERRITOS TRUNK
- City
- artesia
- Loc. details
- Light Highway
- Location Code
- C
- District
- District 19
- Page No.
- 04
- Purpose
- Routine Assessment
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Other
- Height
- 12 in.
- Upstream MH
- 19 0217
- Downstream MH
- 19 0216B
- Dir. of Survey
- Downstream
- Length Surveyed
- 101.7 ft.
- Total Length
- 101.7 ft.
- Structural Index
- 3
- Structural Quick
- 443B
- Structural Rating
- 99
- O&M Index
- 2
- O&M Quick
- 2G00
- O&M Rating
- 76
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 175
Pipe schematic from manhole 19 0217 to 19 0216B Observation photos (3)

2 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

4.7 ft. - Fracture Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

5.7 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 07 to 05 o'clock, , within 8 inches of joint: YES, Start