Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 12, 2020, 07:00 AM
  • 19 0216A_19 0216_06122020_000533.mp4

Date
06/12/2020
W/O
833528
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00718
PipeID
P15186
Time
12:00 AM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7728
Sewer Name
ARTESIA-CERRITOS TRUNK
City
artesia
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 19
Page No.
04
Purpose
Routine Assessment
Project
RFIR_WO_833528_TV19060_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
19 0216A
Downstream MH
19 0216
Dir. of Survey
Downstream
Length Surveyed
71 ft.
Total Length
71 ft.
Structural Index
3
Structural Quick
3B2B
Structural Rating
68
O&M Index
2
O&M Quick
2B00
O&M Rating
28
Overall Index
2
Overall Quick
Overall Rating
96
Pipe schematic from manhole 19 0216A to 19 0216
MH: 19 0216AMH: 19 0216downstream0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. MWL - Water Level, 20 %of cross sectional area0 ft. MGO - General Observation - CONN @ MH 3 O'CLOCK/ACTIVE0 ft. AMH - Upstream Manhole, Survey Begins - 19 0216A2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start2.6 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start35.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"69 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish71 ft. DAE - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Finish71 ft. CM - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish71 ft. MGO - General Observation - CONN @ MH 9 O'CLOCK/ACTIVE71 ft. AMH - Downstream Manhole, Survey Ends - 19 0216

Observation photos (1)

  • Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    2.6 ft. - Crack Multiple, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (13)

DistanceCodeObservation
0MWM
0MWL
2.6CM
71DAE
71CM
69SSS
0MGOCONN @ MH 3 O'CLOCK/ACTIVE
35.2TFC
71MGOCONN @ MH 9 O'CLOCK/ACTIVE
71AMH19 0216
0AMH19 0216A
2.6DAE
2SSS

Properties (7)

additional_info
SC411386
custom_field_three
MULTIPLE CRACKS
custom_field_two
3
customer
1
datetime
2020-06-12T00:00:31-07:00
documentation
PROPIPE
is_lateral_inspection
false