- Date
- 04/27/2020
- W/O
- 828889
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00827
- PipeID
- P17052
- Time
- 2:29 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7620
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- LA VERNE
- Loc. details
- Light Highway
- Location Code
- C
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 15
- Purpose
- Routine Assessment
- Project
- WO_828889_TV22063_MAY2020
- Sewer Type
- Gravity
- Material
- Vitrified Clay Pipe
- Shape
- Circular
- Height
- 12 in.
- Width
- 12 in.
- Upstream MH
- 22 0698
- Downstream MH
- 22 0697
- Dir. of Survey
- Downstream
- Length Surveyed
- 370.2 ft.
- Total Length
- 370.2 ft.
- Structural Index
- 3
- Structural Quick
- 3100
- Structural Rating
- 3
- O&M Index
- 2
- O&M Quick
- 2N1D
- O&M Rating
- 172
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 175
Pipe schematic from manhole 22 0698 to 22 0697 Observation photos (2)

4.5 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

161.6 ft. - Fracture Spiral, from 06 to 09 o'clock, within 8 inches of joint: YES