Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Apr 27, 2020, 10:50 AM
  • 22 0695_22 0694_04272020_041307.mp4

Date
04/27/2020
W/O
828889
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00827
PipeID
P17049
Time
3:50 AM
Certificate
U-715-07000770
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7620
Sewer Name
22 SUNFLOWER TRUNK
City
LA VERNE
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 22
Page No.
15
Purpose
Routine Assessment
Project
WO_828889_TV22063_MAY2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
12 in.
Width
12 in.
Upstream MH
22 0695
Downstream MH
22 0694
Dir. of Survey
Downstream
Length Surveyed
359.9 ft.
Total Length
359.9 ft.
Structural Index
3
Structural Quick
3200
Structural Rating
6
O&M Index
2
O&M Quick
2M14
O&M Rating
144
Overall Index
2
Overall Quick
Overall Rating
150
Pipe schematic from manhole 22 0695 to 22 0694
MH: 22 0695MH: 22 0694downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MWM - Water Mark, 25 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 22 06956.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start7.1 ft. SAV - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start7.1 ft. MGO - General Observation - MAG COATING ATTATCHED30.4 ft. TBA - Tap Break-In Active, at 09 o'clock, -, within 8 inches of joint: NO, 6"99.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"105 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"175.6 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"181 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"252.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: NO, 6"257.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: NO, 6"270.7 ft. LL - Alignment Left, 10 %, Start290.4 ft. LL - Alignment Left, 10 %, Finish358 ft. SAP - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish358 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Finish359.9 ft. AMH - Downstream Manhole, Survey Ends - 22 0694359.9 ft. MGO - General Observation - CONNECTION IN MH, 3 O' CLOCK

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock,  , within 8 inches of joint: YES, Start

    6.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 04 to 08 o'clock, , within 8 inches of joint: YES, Start

  • Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

    7.1 ft. - Surface Aggregate Visible, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

Observations (19)

DistanceCodeObservation
359.9AMH22 0694
0MWL
257.3TFC
175.6TFC
359.9MGOCONNECTION IN MH, 3 O' CLOCK
0MWM
270.7LL
290.4LL
358SAP
358DAGS
7.1SAV
181TFC
6.4DAGS
105TFC
7.1MGOMAG COATING ATTATCHED
0AMH22 0695
252.2TFC
30.4TBA
99.7TFC

Properties (6)

additional_info
SC411170
custom_field_two
3
customer
LACSD
datetime
2020-04-27T03:50:17-07:00
documentation
PROPIPE
is_lateral_inspection
false