Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 22, 2020, 10:51 AM
  • H 0666_H 0665_06222020_035519.mp4

Date
06/22/2020
W/O
833503
Weather
Dry
Operator/Surveyor
J. BUENROSTRO
Sewer ID
Z00941
PipeID
P11073
Time
3:51 AM
Certificate
U-715-07000770
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7803
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
PICO RIVERA
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
03
Purpose
Routine Assessment
Project
RFIR_WO_833503_TV18106_JUN2020
Sewer Type
Siphon
Material
NRCP
Shape
Circular
Height
28 in.
Width
28 in.
Upstream MH
H 0665
Downstream MH
H 0666
Dir. of Survey
Upstream
Length Surveyed
2.4 ft.
Total Length
2.4 ft.
Structural Index
3
Structural Quick
3121
Structural Rating
5
O&M Index
5
O&M Quick
5141
O&M Rating
9
Overall Index
4
Overall Quick
Overall Rating
14
Pipe schematic from manhole H 0665 to H 0666
MH: H 0665MH: H 0666upstream0 ft. SAP - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES0 ft. SSS - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES0 ft. LU - Alignment Up, 45 %0 ft. MSA - Survey Abandoned - VIEW OF SIPHON UPLEG2.4 ft. MWL - Water Level, 100 %of cross sectional area2.4 ft. MWM - Water Mark, 100 %of cross sectional area2.4 ft. AMH - Downstream Manhole, Survey Begins - H 0665

Observation photos (2)

  • Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.4 ft. - Surface Aggregate Projecting, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

    2.4 ft. - Surface Spalling, from 09 to 03 o'clock, within 8 inches of joint: YES

Observations (7)

DistanceCodeObservation
0MWL
0MWM
0AMHH 0665
2.4SAP
2.4SSS
2.4LU
2.4MSAVIEW OF SIPHON UPLEG

Properties (6)

additional_info
SC411613
custom_field_two
5
customer
1
datetime
2020-06-22T03:51:08-07:00
documentation
PROPIPE
is_lateral_inspection
false