Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 24, 2020, 02:56 PM
  • H 0701_H 0700_07242020_084510.mp4

Date
07/24/2020
W/O
833503
Weather
Dry
Operator/Surveyor
N.ZAHREDDINE
Sewer ID
Z00941
PipeID
P11108
Time
7:56 AM
Certificate
U-109-7948
System Owner
1
Date Cleaned
Pre-Cleaning
Not Known
Media Label
K7332
Sewer Name
H JOINT OUTFALL H - UNIT 9B
City
LA PUENTE
Loc. details
Easement/Right of Way
Location Code
D
Use of Sewer
Sanitary Sewer
District
District 18
Page No.
01
Purpose
Routine Assessment
Project
RFIR_WO_833503_TV18106_JUN2020
Sewer Type
Gravity
Material
NRCP
Shape
Circular
Height
25 in.
Width
25 in.
Upstream MH
H 0701
Downstream MH
H 0700
Dir. of Survey
Downstream
Length Surveyed
273.5 ft.
Total Length
273.5 ft.
Structural Index
2
Structural Quick
2J00
Structural Rating
108
O&M Index
2
O&M Quick
2K00
O&M Rating
118
Overall Index
2
Overall Quick
Overall Rating
226
Pipe schematic from manhole H 0701 to H 0700
MH: H 0701MH: H 0700downstream0 ft. AMH - Upstream Manhole, Survey Begins - H 07010 ft. MWL - Water Level, 30 %of cross sectional area0 ft. MWM - Water Mark, 35 %of cross sectional area2 ft. MGO - General Observation - 60% MAG COAT2 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start31.4 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start218.2 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 05 to 07 o'clock, Start - DEBRIS UNDER WATER271 ft. SSS - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Finish272.1 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Finish272.1 ft. OBZ - Obstacles Other, 10 %of cross sectional area, from 05 to 07 o'clock, Finish - DEBRIS UNDER WATER273.5 ft. AMH - Downstream Manhole, Survey Ends - H 0700

Observation photos (1)

  • Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock,  , within 8 inches of joint: YES, Start

    31.4 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 03 to 09 o'clock, , within 8 inches of joint: YES, Start

Observations (11)

DistanceCodeObservation
2MGO60% MAG COAT
0AMHH 0701
271SSS
272.1DAGS
0MWL
0MWM
218.2OBZDEBRIS UNDER WATER
273.5AMHH 0700
272.1OBZDEBRIS UNDER WATER
31.4DAGS
2SSS

Properties (6)

additional_info
SC411327
custom_field_two
3
customer
1
datetime
2020-07-24T07:56:57-07:00
documentation
PRO PIPE
is_lateral_inspection
false