Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jun 24, 2020, 06:32 AM
  • 08 0455A_08 0455_06232020_235109.mp4

Date
06/23/2020
W/O
833500
Weather
Dry
Operator/Surveyor
B.FUGATE
Sewer ID
Z00017
PipeID
P00513
Time
11:32 PM
Certificate
U-508-7069
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7742
Sewer Name
ROCHA STREET TRUNK
City
CARSON
Loc. details
Main Highway - Urban
Location Code
A
Use of Sewer
Sanitary Sewer
District
District 08
Page No.
14
Purpose
Routine Assessment
Project
RFIR_WO_833500_TV08169_JUN2020
Sewer Type
Gravity
Material
Vitrified Clay Pipe
Shape
Circular
Height
30 in.
Width
30 in.
Upstream MH
08 0455A
Downstream MH
08 0455
Dir. of Survey
Downstream
Length Surveyed
129.4 ft.
Total Length
129.4 ft.
Structural Index
3
Structural Quick
3221
Structural Rating
8
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
3
Overall Quick
Overall Rating
8
Pipe schematic from manhole 08 0455A to 08 0455
MH: 08 0455AMH: 08 0455downstream0 ft. AMH - Upstream Manhole, Survey Begins - 08 0455A0 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK0 ft. MGO - General Observation - CONNECTION AT MH 9 O'CLOCK2.1 ft. MGO - General Observation - HEAVY STEAM6.6 ft. CM - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES67.1 ft. CM - Crack Multiple, from 03 to 04 o'clock, within 8 inches of joint: YES103.9 ft. CL - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES129.3 ft. MGO - General Observation - CONNECTION AT MH 3 O'CLOCK CAPPED129.4 ft. AMH - Downstream Manhole, Survey Ends - 08 0455

Observation photos (3)

  • Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

    6.6 ft. - Crack Multiple, from 09 to 03 o'clock, within 8 inches of joint: YES

  • Crack Multiple, from 03 to 04 o'clock, within 8 inches of joint: YES

    67.1 ft. - Crack Multiple, from 03 to 04 o'clock, within 8 inches of joint: YES

  • Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

    103.9 ft. - Crack Longitudinal, at 01 o'clock, within 8 inches of joint: YES

Observations (9)

DistanceCodeObservation
0AMH08 0455A
2.1MGOHEAVY STEAM
0MGOCONNECTION AT MH 3 O'CLOCK
6.6CM
103.9CL
129.3MGOCONNECTION AT MH 3 O'CLOCK CAPPED
129.4AMH08 0455
67.1CM
0MGOCONNECTION AT MH 9 O'CLOCK

Properties (7)

additional_info
SC411751
custom_field_three
SOME CRACKS
custom_field_two
3
customer
1
datetime
2020-06-23T23:32:20-07:00
documentation
PROPIPE
is_lateral_inspection
false