- Date
- 06/05/2020
- W/O
- 828938
- Weather
- Dry
- Operator/Surveyor
- J. BUENROSTRO
- Sewer ID
- Z00827
- PipeID
- P16976
- Time
- 2:08 AM
- Certificate
- U-715-07000770
- System Owner
- LACSD
- Date Cleaned
- —
- Pre-Cleaning
- Not Known
- Media Label
- K7640
- Sewer Name
- 22 SUNFLOWER TRUNK
- City
- SAN DIMAS
- Loc. details
- Main Highway - Urban
- Location Code
- A
- Use of Sewer
- Sanitary Sewer
- District
- District 22
- Page No.
- 21
- Purpose
- Routine Assessment
- Project
- RFIR_WO_828938_TV22166_MAY2020
- Sewer Type
- Gravity
- Material
- NRCP
- Shape
- Circular
- Height
- 15 in.
- Width
- 15 in.
- Upstream MH
- 22 0628
- Downstream MH
- 22 0627
- Dir. of Survey
- Downstream
- Length Surveyed
- 369.9 ft.
- Total Length
- 369.9 ft.
- Structural Index
- 3
- Structural Quick
- 3N2N
- Structural Rating
- 365
- O&M Index
- 2
- O&M Quick
- 2N00
- O&M Rating
- 146
- Overall Index
- 2
- Overall Quick
- —
- Overall Rating
- 511
Pipe schematic from manhole 22 0628 to 22 0627 Observation photos (3)

3.1 ft. - Surface Spalling, from 08 to 04 o'clock, within 8 inches of joint: YES, Start

3.3 ft. - Deposits Attached Encrustation, 5 %of cross sectional area, from 08 to 04 o'clock, , within 8 inches of joint: YES, Start

3.3 ft. - Surface Aggregate Projecting, from 08 to 04 o'clock, within 8 inches of joint: YES, Start