Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 24, 2020, 04:58 AM
  • C 0443_C 0442_07232020_220324.mp4

Date
07/23/2020
W/O
833637
Weather
Dry
Operator/Surveyor
S. LOPEZ
Sewer ID
Z00128
PipeID
P09648
Time
9:58 PM
Certificate
U-0720-70309212
System Owner
1
Date Cleaned
Pre-Cleaning
No Pre-Cleaning
Media Label
K7881
Sewer Name
JOINT OUTFALL C - UNIT 5A REPLACEMENT
City
LONG BEACH
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 03
Page No.
24
Purpose
Routine Assessment
Project
RFIR_WO_833637_TV03175_JUN2020
Sewer Type
Siphon
Material
Vitrified Clay Pipe
Shape
Circular
Height
27 in.
Width
36 in.
Upstream MH
C 0442
Downstream MH
C 0443
Dir. of Survey
Upstream
Length Surveyed
2 ft.
Total Length
2 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
4
O&M Quick
5121
O&M Rating
7
Overall Index
4
Overall Quick
Overall Rating
7
Pipe schematic from manhole C 0442 to C 0443
MH: C 0442MH: C 0443upstream0 ft. DAGS - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES0 ft. MSA - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.2 ft. MWM - Water Mark, 100 %of cross sectional area2 ft. MWL - Water Level, 100 %of cross sectional area2 ft. MGO - General Observation - CONN @ MH 10 O' CLOCK/UNKNOWN2 ft. AMH - Downstream Manhole, Survey Begins - C 0442

Observation photos (2)

  • Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock,  , within 8 inches of joint: YES

    2 ft. - Deposits Attached Grease, 5 %of cross sectional area, from 10 to 02 o'clock, , within 8 inches of joint: YES

  • Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

    2 ft. - Survey Abandoned - VIEW OF UPLEG OF D/S SIPHON.

Observations (6)

DistanceCodeObservation
0MWM
0MWL
2DAGS
2MSAVIEW OF UPLEG OF D/S SIPHON.
0MGOCONN @ MH 10 O' CLOCK/UNKNOWN
0AMHC 0442

Properties (8)

additional_info
SC411721
custom_field_three
WATER LEVEL TOO HIGH
custom_field_two
5
customer
1
datetime
2020-07-23T21:58:54-07:00
documentation
PROPIPE
is_lateral_inspection
false
year_laid
31350