Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 22, 2020, 07:07 AM
  • 15 0773_15 0772_7222020_001047.mp4

Date
07/22/2020
W/O
0839422
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12974
Time
12:07 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1489R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20200721MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 0773
Downstream MH
15 0772
Dir. of Survey
Downstream
Length Surveyed
400.7 ft.
Total Length
400.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
2
O&M Quick
3323
O&M Rating
20
Overall Index
2
Overall Quick
Overall Rating
20
Pipe schematic from manhole 15 0773 to 15 0772
MH: 15 0773MH: 15 0772downstream0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN 3:00 ACTIVE0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. AMH - Upstream Manhole, Survey Begins - 12:15AM14.6 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open25.7 ft. RFJ - Roots Fine Joint, from 02 to 04 o'clock, within 8 inches of joint: YESR - 4%81.3 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped92.4 ft. RMJ - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR108.4 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 1%113.9 ft. RFJ - Roots Fine Joint, from 01 to 05 o'clock, within 8 inches of joint: YESR - 4%130 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped133.3 ft. TB - Tap Break-In, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open253.6 ft. RFJ - Roots Fine Joint, from 08 to 10 o'clock, within 8 inches of joint: YESR - 1%266 ft. RFJ - Roots Fine Joint, from 08 to 04 o'clock, within 8 inches of joint: YESR - 1%270.6 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped273.5 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped317.4 ft. RMJ - Roots Medium Joint, from 08 to 03 o'clock, 5 %, within 8 inches of joint: YESR321.9 ft. RMC - Roots Medium Connection, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES321.9 ft. TFD - Tap Factory Made Defective, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open-100% ROOTS324.6 ft. RTC - Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES324.6 ft. TFD - Tap Factory Made Defective, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Open-100% ROOTS400.2 ft. MGO - General Observation - MH CONN 3:00 ACTIVE400.2 ft. MGO - General Observation - MH CONN 9:00 ACTIVE400.7 ft. AMH - Downstream Manhole, Survey Ends - 12:45AM

Observation photos (3)

  • Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

    92.4 ft. - Roots Medium Joint, from 08 to 04 o'clock, 15 %, within 8 inches of joint: YESR

  • Roots Medium Connection, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES

    321.9 ft. - Roots Medium Connection, from 07 to 11 o'clock, 25 %, within 8 inches of joint: YES

  • Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES

    324.6 ft. - Roots Tap Connection, from 01 to 02 o'clock, 10 %, within 8 inches of joint: YES

Observations (24)

DistanceCodeObservation
130TFCCapped
321.9RMC
266RFJ1%
113.9RFJ4%
273.5TFCCapped
270.6TFCCapped
400.7AMH12:45AM
0MWL
81.3TFCCapped
400.2MGOMH CONN 3:00 ACTIVE
14.6TFOpen
108.4RFJ1%
92.4RMJ
25.7RFJ4%
321.9TFDOpen-100% ROOTS
0MGOMH CONN 3:00 ACTIVE
253.6RFJ1%
324.6RTC
0MWM
324.6TFDOpen-100% ROOTS
133.3TBOpen
400.2MGOMH CONN 9:00 ACTIVE
0AMH12:15AM
317.4RMJ

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-07-22T00:07:18-07:00
documentation
MARTIN,OLIVER 111,SHADLER,BARR
is_lateral_inspection
false