Sanitation Districts of Los Angeles Countyt4 Spatial
Wastewater/Activity/PacpInspection/1.0Jul 21, 2020, 07:31 AM
  • 15 1168_15 0780_7212020_003512.mp4

Date
07/21/2020
W/O
0839422
Weather
Dry
Operator/Surveyor
MARTIN
Sewer ID
Z00593
PipeID
P12982
Time
12:31 AM
Certificate
U-1014-06022543
System Owner
LACSD
Date Cleaned
Pre-Cleaning
Not Known
Media Label
H1488R
Sewer Name
15 ARCADIA-SIERRA MADRE TRUNK, SECTS 2&5
City
ARCADIA
Loc. details
Light Highway
Location Code
C
Use of Sewer
Sanitary Sewer
District
District 15
Page No.
04
Purpose
Maintenance Related
Project
20200721MDM_ARCADIA_SIERRA_MADRE_TRUNK_SECTS_2_5
Material
NRCP
Shape
Circular
Height
15 in.
Upstream MH
15 1168
Downstream MH
15 0780
Dir. of Survey
Downstream
Length Surveyed
145.7 ft.
Total Length
145.7 ft.
Structural Index
0
Structural Quick
0000
Structural Rating
0
O&M Index
0
O&M Quick
0000
O&M Rating
0
Overall Index
0
Overall Quick
Overall Rating
0
Pipe schematic from manhole 15 1168 to 15 0780
MH: 15 1168MH: 15 0780downstream0 ft. AMH - Upstream Manhole, Survey Begins - 12:35AM0 ft. MWM - Water Mark, 30 %of cross sectional area0 ft. MWL - Water Level, 10 %of cross sectional area0 ft. MGO - General Observation - MH CONN 9:00 ACTIVE29.7 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped51.7 ft. TFC - Tap Factory Made Capped, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Capped63.2 ft. TFC - Tap Factory Made Capped, at 02 o'clock, -, within 8 inches of joint: YES, 6" - Capped84.8 ft. TF - Tap Factory Made, at 10 o'clock, -, within 8 inches of joint: YES, 6" - Open145 ft. MGO - General Observation - MH CONN 9:00 ACTIVE145.7 ft. AMH - Downstream Manhole, Survey Ends - 12:45AM

Observations (10)

DistanceCodeObservation
0AMH12:35AM
0MWM
51.7TFCCapped
0MWL
84.8TFOpen
29.7TFCCapped
145MGOMH CONN 9:00 ACTIVE
63.2TFCCapped
145.7AMH12:45AM
0MGOMH CONN 9:00 ACTIVE

Properties (5)

additional_info
POST ROOT EVALUATION ONLY
customer
LACSD
datetime
2020-07-21T00:31:29-07:00
documentation
MARTIN,OLIVER 111,SHADLER,BARR
is_lateral_inspection
false